        Weifang Newheek professional manufacture all kinds of Medical Bucky Stand 、Medical X-ray Machine 、、Digital X-Ray Machine 、Industrial Inspection X-Ray Machine .

        山東華銳影像設備有限公司

        Hotline

        NKX-400 Mobile X-ray machine DR System

        Main configuration Technical Parameters X ray tube 1. Bifocal size (small / large): 0.6 / 1.2 mm 2. Maximum rated power @ 0.1s: 1 6 / 32kW @ 50 Hz Maximum tube current: 200/400 mA @ 50 Hz Maximum tube voltage: 150 kVp 3. Anode thermal capac……
        Product Introduction

        Main configuration Technical Parameters    
         
         
        X ray tube
        1. Bifocal size (small / large): 0.6 / 1.2 mm
        2. Maximum rated power @ 0.1s: 1 6 / 32kW @ 50 Hz
        Maximum tube current: 200/400 mA @ 50 Hz
        Maximum tube voltage: 150 kVp
        3. Anode thermal capacity: 220 kHU, anode angle: 12 °, anode rotation speed: 2700 rpm @ 50 Hz
        4. Focus center: The center of focus of the X-ray tube assembly is balanced at any position within the range of 1250 ~ 1900 mm, and the braking is reliable.
        5. X-ray tube range:
        1) The highest position from the ground is ≥ 1850 mm, and the lowest position is 950 mm;
        2) The reference axis can be turned laterally by ± 90 ° (± 5 °)    
         
        X ray collimator
        1. Minimum inherent filtration: 1mmAl
        2. Power supply: AC / DC 24V 150W
        3. Maximum tube voltage: 150kVP
        4. When SID = 1m, the maximum radiation field is ≥ 43cm * 43cm    
         
        Wireless flat panel detector
        1. Technology used: amorphous silicon TFT and photodiode;
        2. Image size: 17 "× 17";
        3. Spatial resolution: 3.5p / mm;
        4. Detection gray level (A / D bit number): 16 bit;
        5. Data interface: Gigabit Ethernet;
        6. Holographic acquisition time: ≤4s;
        7. Pixels: 3072X3072 pixels
        8. Wireless transmission
        Note: Continued from the form on the previous page
         
        Main configuration Technical Parameters    
         
         
         
         
         
         
        HV Generator
         
         
         
        Power requirements
        Single-phase sinusoidal AC: non-sinusoidal distortion less than 2% of its amplitude    
          Power supply voltage: 220VAC ± 10%    
          Power frequency: 50Hz    
          Power supply internal resistance: not more than 1Ω    
          Power capacity: 3.5 KVA    
         
        General parameters
        Output power: 32 KW    
          Rated voltage: 220VAC ± 10%    
          Inverter frequency: 60kHz    
         
        Exposure parameters Exposure kV range: 40kV-125kV, 1kV step    
          Exposure mA range: 10-400mA    
          Exposure ms range: 1.-6300ms    
         
         
         
        The main parameters kV adjustment button: single arrow adjustment step is 1kV. Range: 40 to 150KV (accuracy ± 10%)    
          mA adjustment button: single arrow adjustment according to R’20 rule, accuracy ± 20%    
          ms adjustment button: single arrow adjustment according to R 20 rule, accuracy ± 10% + 1ms    
          Maximum output power: 20kW    
          X-ray tube voltage: 100kV    
          X-ray tube current: 200mA    
          Nominal output power: 20 kW (100 kV³200 mA)    
          Nominal tube voltage and corresponding maximum tube current: 125kV    
          Nominal tube current and corresponding maximum tube voltage: 200mA 100kV
        Mobile X-ray machine DR System
         

        prevHigh frequency mobile X-ray machine
        next
        ?
        ? 天天干天天日
      4. <dd id="mz4tp"><track id="mz4tp"><noframes id="mz4tp"></noframes></track></dd>