<th id="vwah9"></th>

  • <button id="vwah9"><acronym id="vwah9"><u id="vwah9"></u></acronym></button>
    <li id="vwah9"><acronym id="vwah9"></acronym></li>
  • <dd id="vwah9"><pre id="vwah9"></pre></dd>

      ?

      Weifang Newheek professional manufacture all kinds of Medical Bucky Stand 、Medical X-ray Machine 、、Digital X-Ray Machine 、Industrial Inspection X-Ray Machine .

      山東華銳影像設備有限公司

      Hotline

      NKX-400 Mobile X-ray machine DR System

      Main configuration Technical Parameters X ray tube 1. Bifocal size (small / large): 0.6 / 1.2 mm 2. Maximum rated power @ 0.1s: 1 6 / 32kW @ 50 Hz Maximum tube current: 200/400 mA @ 50 Hz Maximum tube voltage: 150 kVp 3. Anode thermal capac……
      Product Introduction

      Main configuration Technical Parameters    
       
       
      X ray tube
      1. Bifocal size (small / large): 0.6 / 1.2 mm
      2. Maximum rated power @ 0.1s: 1 6 / 32kW @ 50 Hz
      Maximum tube current: 200/400 mA @ 50 Hz
      Maximum tube voltage: 150 kVp
      3. Anode thermal capacity: 220 kHU, anode angle: 12 °, anode rotation speed: 2700 rpm @ 50 Hz
      4. Focus center: The center of focus of the X-ray tube assembly is balanced at any position within the range of 1250 ~ 1900 mm, and the braking is reliable.
      5. X-ray tube range:
      1) The highest position from the ground is ≥ 1850 mm, and the lowest position is 950 mm;
      2) The reference axis can be turned laterally by ± 90 ° (± 5 °)    
       
      X ray collimator
      1. Minimum inherent filtration: 1mmAl
      2. Power supply: AC / DC 24V 150W
      3. Maximum tube voltage: 150kVP
      4. When SID = 1m, the maximum radiation field is ≥ 43cm * 43cm    
       
      Wireless flat panel detector
      1. Technology used: amorphous silicon TFT and photodiode;
      2. Image size: 17 "× 17";
      3. Spatial resolution: 3.5p / mm;
      4. Detection gray level (A / D bit number): 16 bit;
      5. Data interface: Gigabit Ethernet;
      6. Holographic acquisition time: ≤4s;
      7. Pixels: 3072X3072 pixels
      8. Wireless transmission
      Note: Continued from the form on the previous page
       
      Main configuration Technical Parameters    
       
       
       
       
       
       
      HV Generator
       
       
       
      Power requirements
      Single-phase sinusoidal AC: non-sinusoidal distortion less than 2% of its amplitude    
        Power supply voltage: 220VAC ± 10%    
        Power frequency: 50Hz    
        Power supply internal resistance: not more than 1Ω    
        Power capacity: 3.5 KVA    
       
      General parameters
      Output power: 32 KW    
        Rated voltage: 220VAC ± 10%    
        Inverter frequency: 60kHz    
       
      Exposure parameters Exposure kV range: 40kV-125kV, 1kV step    
        Exposure mA range: 10-400mA    
        Exposure ms range: 1.-6300ms    
       
       
       
      The main parameters kV adjustment button: single arrow adjustment step is 1kV. Range: 40 to 150KV (accuracy ± 10%)    
        mA adjustment button: single arrow adjustment according to R’20 rule, accuracy ± 20%    
        ms adjustment button: single arrow adjustment according to R 20 rule, accuracy ± 10% + 1ms    
        Maximum output power: 20kW    
        X-ray tube voltage: 100kV    
        X-ray tube current: 200mA    
        Nominal output power: 20 kW (100 kV³200 mA)    
        Nominal tube voltage and corresponding maximum tube current: 125kV    
        Nominal tube current and corresponding maximum tube voltage: 200mA 100kV